      Industrial robot body maintenance

      Date:2021-01-22 Reading:
      Industrial robot body maintenance
      1. General maintenance
      1) Cleaning robot
      Clean the manipulator base and arms regularly; high-pressure cleaning equipment can be used, but direct spraying to the manipulator should be avoided; if the manipulator is protected by a grease film, remove it as required. (Avoid using strong solvents such as acetone, avoid using plastic protection, and to prevent static electricity, you must use a wet or damp cloth to wipe non-conductive surfaces, such as spray equipment, hoses, etc.. Do not use dry cloths.)
      2) Cleaning and maintenance of hollow wrist
      According to the actual situation, hollow wrists need to be cleaned frequently to avoid accumulation of dust and particles. Use a clean cloth that does not contain pompoms for cleaning. After washing the wrist, you can add a small amount of petroleum jelly or similar substances to the surface of the wristwatch, which will be more convenient for subsequent cleaning. .
      3) Regular inspection
      Check for oil leakage; check whether the gear clearance is too large; check whether the cables between the control cabinet, purge unit, process cabinet and manipulator are damaged.
      4) Inspection of fixing bolts
      The fastening bolts and fixing clamps that fix the manipulator on the foundation must be kept clean and must not be in contact with corrosive liquids such as water, acid and alkali solutions. If the anti-corrosion protective layer such as galvanized layer or paint is damaged, the related parts need to be cleaned and coated with anti-corrosion paint.
      2. Shaft brake test
      During operation, each axis motor brake will wear out normally. To determine whether the brake is working properly, a test must be performed at this time.
      Test method: Check the brake of each axis motor as described below.
      1) Run the manipulator axis to the corresponding position, where the total weight of the manipulator and all loads reach the maximum value (maximum static load);
      2) Power off the motor;
      3) Check whether all axes are maintained in their original positions;
      If the manipulator does not change its position when the motor is powered off, the braking torque is sufficient. You can also move the manipulator manually to check whether further protective measures are needed. When the mobile robot stops in an emergency, the brake will help to stop, so wear may occur. Therefore, repeated tests are required during the service life of the machine to verify whether the machine maintains its original capacity.
      3. System lubrication and oiling
      1) Lubrication of shaft and pinion gears and gears
      Make sure that the robot and related systems are closed and locked. Squeeze a little (1g) of grease into each grease nipple, lubricate the pinion gear grease nipple and each gear grease nipple one by one. Do not inject too much to avoid damage to the seal.
      2) Lubricate the hollow wrist
      There are 10 lubrication points for the hollow wrist. Each grease nozzle only needs a few drops of lubricant (1g). Do not inject excessive lubricant to avoid damage to the wrist seal and internal sleeve.
      4. Check the oil level in each gear box
      The positions of the lubricating holes of each shaft are different, and a targeted inspection is required. Some of them need to be rotated and placed in a vertical state before opening the cover for inspection.
      5. Maintenance cycle (time interval can be adjusted appropriately according to environmental conditions, robot operating hours and temperature)
      1) Ordinary maintenance frequency: 1 time/day;
      2) Shaft brake test: 1 time/day;
      3) Lubrication of 3-axis pinion and gear: 1 time/1000H;
      4) Lubricate hollow wrist: 1 time/500H;
      5) Lubricating oil in each gear box: replace it for the first time one year, and then every five years.
      2. Maintenance of the system control cabinet
      1. Maintenance content
      1) Check the heat dissipation of the controller
      It is strictly forbidden to cover the controller with plastic or other materials; leave enough space between the back and side of the controller (>120mm); it is strictly forbidden to place the controller close to the heat source; it is strictly forbidden to put sundries on the top of the controller; Multiple cooling fans do not work; avoid clogging of the fan inlet or outlet; avoid dirty air filter cloth; when the controller is not performing work, its front door must be kept closed.
      2) Clean the teach pendant
      The teach pendant should be cleaned at an appropriate frequency based on actual needs; although the panel paint film can withstand the corrosion of most solvents, avoid contact with strong solvents such as acetone; the teach pendant should be removed and placed in a clean place when not in use. place.
      3) Clean the inside of the controller
      The inside of the controller should be cleaned at appropriate intervals based on environmental conditions, such as once a year; special attention must be paid to the cleaning of the cooling fan and the air inlet/outlet. Use a dust-removing brush when cleaning, and use a vacuum cleaner to suck up the dust. Do not use a vacuum cleaner to clean the components directly, otherwise it will cause electrostatic discharge and damage the components; be sure to cut off before cleaning the inside of the controller!
      4) Clean or replace the filter cloth
      To clean the filter cloth, it is necessary to clean the filter cloth 3-4 times in 30-40℃ water with detergent. Do not wring out the filter cloth, but place it on a flat surface to dry. You can also use clean compressed air to blow the filter cloth clean.
      5) Replace the battery regularly
      The measurement system battery is a disposable battery (non-rechargeable battery); when the battery is replaced, a message will appear in the message log. After the message appears, the battery power can be maintained for about 1800 hours. (It is recommended to replace the battery when the above message appears) The battery only works when the control cabinet is "powered off". The battery life is about 7000 hours.
      If the control cabinet controls the CBS unit in addition to the robot, or in the case of an 8-axis robot, the battery life is half as described above (using 2 SMU units).
      6) Check the cooler
      The cooling circuit adopts a maintenance-free closed system design, and each component of the external air circuit needs to be regularly checked and cleaned as required; when the environmental humidity is high, it is necessary to check whether the drain outlet is regularly drained.
      2. Maintenance frequency (time interval can be adjusted appropriately according to environmental conditions, robot operating hours and temperature)
      1) General maintenance: 1 time/day;
      2) Cleaning/replacement of filter cloth: 1 time/500H;
      3) Battery replacement of the measurement system: 2 times/7000H;
      4) Replacement of computer fan unit and servo fan unit: 1 time/50000H;
      5) Check the cooler; 1 time/month.


      Share:
      主站蜘蛛池模板: 高清国产精品人妻一区二区| 亚洲成在人线在线播放无码| 亚洲国产精品成人无码区| 久久久久国产精品麻豆ar影院| 国产在线精品第一区二区| 久久男人av资源网站无码| 午夜一区二区亚洲福利| 亚洲一区二区中文字幕| 国产av无码专区亚洲av软件| 少妇精品视频无码专区| 亚洲综合无码一区二区痴汉| 暴力调教一区二区三区| 国产国产成人精品久久蜜| 一本之道av不卡精品| 亚洲精品久久久久午夜福禁果tⅴ 亚洲国产精品成人无码区 | 国产视频一区二区在线观看| 久久精品av一区二区免费| 狠狠精品久久久无码中文字幕| 国产精品制服丝袜无码| 深田えいみ禁欲后被隔壁人妻 | 亚洲女同精品一区二区| 中文字幕乱码无遮挡精品视频| 亚洲视频二| 亚洲偷自拍另类图片二区| 强奷乱码中文字幕熟女一| 国产成人手机高清在线观看网站| 国产69久久精品成人看| 自拍偷自拍亚洲精品播放| 99久久精品费精品国产一区二| 日韩色无码一级毛片一区二区-百 久久人妻内射无码一区三区 | 亚洲精品一区二区天堂| 国产欧美另类久久精品蜜芽| 日韩精品亚洲专在线电影| 欧美va亚洲va在线观看| 久久精品无码av| YW尤物AV无码国产在线观看| 国产第八页| 国产精品网址你懂的| 国产在线精品无码二区二区| 亚洲色大成网站WWW永久麻豆| 国产午夜福利精品一区二区三区|